gateway-watchdog
Windows background watchdog for the OpenClaw Gateway: 5s health checks, auto-restart on crash, hidden no-window operation, tray status icon, and a maintenance lock that keeps repairs (doctor --fix) from racing the watchdog. Auto-repair is OFF by default; the watchdog only restarts the Gateway.
Gateway Watchdog
A Windows background watchdog for the OpenClaw Gateway. It health-checks the Gateway every 5 seconds, automatically restarts it when it goes down, and runs hidden in the background — no CMD window — with a system-tray status icon.
Its key feature is a maintenance lock: while a repair such as doctor --fix
is running, the watchdog suspends all health checks and restart attempts, so the
two never fight each other. Version-agnostic path resolution, HTTP-first health
probing, log rotation, and deadlock-safe lock expiry are all included.
When to Use
- Gateway keeps crashing / restarting in a loop
- Watchdog log spams
!! Gateway OFFLINEeven though the port is listening - A
doctor --fixrun keeps getting interrupted by the watchdog trying to restart - You want the Gateway + watchdog to run hidden (no CMD window)
- Installing or repairing the watchdog service on Windows
Architecture
| Piece | File | Role |
|---|---|---|
| Watchdog | scripts/watchdog.ps1 | Main loop, health check, restart, tray icon |
| Maintenance wrapper | scripts/watchdog-maintenance.ps1 | Run a repair while holding the lock |
| Hidden launcher | scripts/run_gateway_silent.vbs | Start Gateway with no window |
| Gateway script | scripts/gateway.cmd | Dynamic path resolution, no version pin |
| Installer | scripts/install_watchdog_admin.bat | One-shot admin setup for scheduled tasks |
Single-instance guard (v1.1.0)
The watchdog holds a named mutex for its whole lifetime:
$MUTEX_NAME = "Global\OpenClawWatchdog_SingleInstance"
$script:mutex = New-Object System.Threading.Mutex($false, $MUTEX_NAME)
$gotIt = $script:mutex.WaitOne(0)
if (-not $gotIt) { exit 0 }
Why this exists. v1.0.0 was launched by a 5-minute repetition trigger while
its own while ($true) loop never exited. Eight copies stacked in 25 minutes,
each polling the same status file and drawing its own tray icon. Fix has two
halves and both are required:
- Trigger — a long-running loop gets a logon trigger only. Repetition is for scripts that exit on their own.
- Code — the mutex above, so an unexpected launch path is harmless.
Verify a second copy really dies:
Start-Process wscript.exe -ArgumentList 'run_watchdog_silent.vbs' -WindowStyle Hidden
Start-Sleep -Seconds 6
@(Get-CimInstance Win32_Process | Where-Object { $_.CommandLine -match 'watchdog\.ps1' }).Count
# must be 1
How the Maintenance Lock Works
The lock file is ~/.openclaw/watchdog-maintenance.lock (JSON: owner, pid, createdAt).
- Any repair routine creates the lock before it starts.
- While a fresh lock exists, the watchdog pauses all health judgement and restart attempts, and switches the tray icon to "maintenance".
- A lock older than
LOCK_STALE_SEC(default 300s) is treated as abandoned and removed automatically (dead-lock protection). - The lock is re-checked immediately before any restart, so maintenance that begins mid-wait still wins.
- The lock is released in a
finallyblock, always.
Usage
Check status
Get-Content "$env:USERPROFILE\.openclaw\watchdog-status.json" -Raw
Get-Content "$env:USERPROFILE\.openclaw\watchdog.log" -Tail 20
The status file holds: state (starting/ok/down/restarting/maintenance), cycle,
failCount, updatedAt, uptimeMin.
Run a repair safely (coordinated with the watchdog)
powershell -NoProfile -File "$env:USERPROFILE\.openclaw\workspace\watchdog-maintenance.ps1" doctor --fix --non-interactive
The wrapper takes the lock, runs the command, releases the lock. Never run a repair bare while the watchdog is live — it will fight you.
Install / repair (needs Administrator)
Right-click -> Run as administrator:
install_watchdog_admin.bat
This switches the Gateway task to the hidden VBS launcher, updates the Watchdog task to run hidden PowerShell, restarts the Gateway silently, and verifies the port.
Tray States
- Shield — healthy
- Warning — restarting
- Info — maintenance in progress
- Error — offline
$SHOW_TRAY = $false in watchdog.ps1 disables the tray (headless mode). Without
an interactive session the tray is skipped automatically — the status file is
still written.
Tuning (watchdog.ps1 top block)
| Var | Default | Meaning |
|---|---|---|
$CHECK_INTERVAL | 5 | seconds between checks |
$GATEWAY_PORT | 18789 | Gateway port |
$RESTART_THRESHOLD | 2 | consecutive failures before restart |
$LOCK_STALE_SEC | 300 | abandoned-lock timeout |
$DOCTOR_TIMEOUT_SEC | 90 | max doctor --fix runtime |
$DOCTOR_COOLDOWN_MIN | 10 | min gap between doctor runs |
$SELF_REFRESH_HOURS | 24 | relaunch self before shell limits |
The Four Scheduled-Task Flaws (v3 fix)
A default schtasks install of this watchdog can die silently. Four compounding causes:
| # | Flaw | Symptom | v3 fix |
|---|---|---|---|
| 1 | Trigger is LogonTrigger only | Killed once, never comes back | RestartOnFailure 999x/1min + a Guard task |
| 2 | StopOnIdleEnd=true | Task killed when you return to the PC (exit 0xC000013A) | Explicitly set false |
| 3 | Self-refresh exits without confirming the replacement | Coverage gap if the new process fails | Wait for the status-file pid to change; stay alive otherwise |
| 4 | No independent supervisor | Nothing restarts a dead watchdog | \OpenClaw Watchdog Guard task, every 5 min |
Hard-won gotchas
- Do not delete
<IdleSettings>- Task Scheduler re-adds it with defaults (StopOnIdleEnd=true). Always write the block explicitly withfalse. - Never edit
.ps1through a JSON/JS string tool - escaping layers collide; corruption is offset, so the reported error line is not the real one. Write a small patch.ps1and use[System.IO.File]::WriteAllText/WriteAllLines. - Placeholder order matters: if
__WD__lives inside the__GUARD__value, replace__GUARD__first, then__WD__. schtasks /Create /XMLvalidates syntax, not substitutions. Re-read viaschtasks /query /tn <name> /xmland assert no__remains.- Changing a scheduled task needs Administrator. Non-admin
schtasks /Changegives Access denied. - Do not use a read-tool result as a write basis when a file looks wrong - a truncation/placeholder notice can be written back as file content. Read raw bytes with
[System.IO.File]::ReadAllTextbefore rewriting.
Verify after install
schtasks /query /tn "OpenClaw Watchdog" /xml | Select-String StopOnIdleEnd
schtasks /query /tn "OpenClaw Watchdog Guard" /xml | Select-String Arguments
Get-CimInstance Win32_Process | Where-Object { $_.CommandLine -like '*watchdog.ps1*' }
Get-Content "$env:USERPROFILE\.openclaw\watchdog.log" -Tail 10
Known minor issue
The Guard task can occasionally start a second watchdog process. Functionally harmless; tighten the CommandLine filter if you want strict single-instance.
Security & scope disclosure (v1.2.0)
Added after a ClawHub audit on 2026-10-27. Read before installing.
What requires elevation: only the installer, and only to change two scheduled task actions. The watchdog process itself runs as the logged-in user.
What runs hidden: the Gateway launcher (run_gateway_silent.vbs) and the
watchdog (run_watchdog_silent.vbs). Hidden operation is the point — Task
Scheduler would otherwise flash a console window every cycle — but you should
know it is happening. watchdog.log and watchdog-status.json record every
action; the tray icon shows current state.
Persistence: both tasks carry a Logon trigger, so they survive reboot. See
README.md for the exact disable and uninstall steps.
Process termination is scoped. v1.1.0 and earlier ran
taskkill /f /im node.exe and taskkill /f /im wscript.exe from the elevated
installer, which could kill unrelated Node.js and Windows Script Host workloads.
v1.2.0 never kills by image name; it stops and starts the named scheduled task
and nothing else.
Auto-repair is opt-in. The watchdog no longer runs openclaw doctor --fix
on its own. Restart-only is the default. Set $AUTO_DOCTOR = $true at the top of
watchdog.ps1 if you want a hidden background process to modify local OpenClaw
state automatically.
The maintenance wrapper is allowlisted. watchdog-maintenance.ps1 used to
execute whatever command it was given. It now matches the full argument vector
against a fixed list and exits 3 on anything else. Run it with list to see
what is permitted.
Uninstall
Stop-ScheduledTask -TaskName 'OpenClaw Watchdog' -ErrorAction SilentlyContinue
Unregister-ScheduledTask -TaskName 'OpenClaw Watchdog' -Confirm:$false
Get-CimInstance Win32_Process | Where-Object { $_.CommandLine -match 'watchdog\.ps1' } |
ForEach-Object { Stop-Process -Id $_.ProcessId -Force }
Remove-Item "$env:USERPROFILE\.openclaw\workspace\watchdog.ps1" -ErrorAction SilentlyContinue
To pause without uninstalling: Disable-ScheduledTask -TaskName 'OpenClaw Watchdog'
Troubleshooting
!! Gateway OFFLINEwhile port is listening — usually a restart-timing race; HTTP probe first. If persistent, check the maintenance lock is not stuck.- Watchdog cannot enter maintenance mode /
schtasksAccess denied — the scheduled task needs Administrator. Run the installer as admin. - Two watchdogs running — end the old instance with PowerShell
Stop-Process. - Gateway starts but window pops — the task still points at
gateway.cmd; re-run the installer to switch it torun_gateway_silent.vbs.
License
MIT-0 — see LICENSE.
Related skills
- Downloads
- 328All time
- Security audit
- Review
- Last updated
- 3d ago
- Current version
- v0.0.2
- License
- MIT-0